Skip to main content
plas-tech engineering - Supplier for COC/COP PFS Syringes
Schreiner
rochling

Login Menu

  • Login
  • Register
Home
  • HOME
  • CONNECTIONS
    • Suppliers
    • Buyers
    • Professionals
    • User Companies
    • Softwares
    • Others
  • INDUSTRY UPDATES
    • Packaging News
    • Innovations
    • Press Releases
    • Events
    • Resources
    • Newsletter
    • Testimonials
    • Packaging Interviews
    • Packaging 4 startups
  • BLOG
  • OUR PRODUCTS
    • Big Book of Packaging
  • OUR PARTNERS
    • Bonini
    • Bernhardt
    • EMA
    • Haemotronic
    • Intin
    • Plas-Tech Engineering
    • Polycine
    • Rochling
    • Sanok Rubber
    • Schreiner
    • TARA
    • Yukon Medical
  • SERVICES
    • SUSTAINABLE EXHIBITION
    • CONSULTING
    • DESIGN SERVICES
    • NEWSLETTER SUBSCRIPTION

Breadcrumb

  1. Home
  2. Advanced R&D isolator for decontamination and oxidation studies

Advanced R&D isolator for decontamination and oxidation studies

Profile picture for user pr011
By Press Packagin… on Sat, 02/01/2020 - 12:49

Once the decontamination phase of the VPHP cycle is over, an aeration phase starts with the aim to rapidly decrease the vapour of hydrogen peroxide up to the concentration of 1 ppm. In fact, 1 ppm has been officially defined by the National Institute of Occupational Safety and Health (NIOSH) as the daily safety value for the operators and for the exposure of the production materials3.

Recently, several studies focused on the hydrogen peroxide residues upon the decontamination cycle and critical effects on the pharmaceutical products are now emerging. The oxidation of pharmaceutical molecules, the dissolution into liquid products and the adsorption within medical materials are just few consequences of the effect of sub-ppm VPHP concentrations4–6.

For instance, concerning the biotech pharmaceutical compounds that contain many aminoacidic residues sensitive to oxidative potentials, it does not represent a negligible topic. In fact, several groups are trying to mathematically model the effects of sub-ppm concentrations of hydrogen peroxide on their pharmaceutical products7–9.

In order to make available a tool allowing to experimentally investigate the various effects of sub-ppm VPHP concentrations, Comecer engineered a standard VPHP-sterility tester isolator with H2O2 “Ultra-Low” capabilities.

The modified isolator can firmly control VPHP concentrations ranging from 5 part-per-billion (ppb) to few ppm through a system referred to as Ultra-Low VPHP (UL-VPHP).

The core of the UL-VPHP system is represented by the hydrogen peroxide Picarro probe (Picarro PI2114 spectrometric gas concentration analyser, hereafter referred to as Picarro) that allows an online continuous measurement of VPHP concentration inside the isolator.

Based on the output signals of the Picarro, the system automatically adjusts the VPHP levels by increasing (inducing a “hot” response) and decreasing (inducing a “cold” response) the total amount of hydrogen peroxide inside the isolator in order to keep it stable within a ± 5 ppb range with respect to the desired value.

The “hot” response is involved in increasing the VPHP concentration; it takes advantage of specific designed system able to release minimal amount of H2O2 aerosol. VPHP-loaded air is then directly injected within the isolator’s chamber, thus increasing the VPHP level. On the other side, the lowering of VPHP levels is based on the “cold” feedback, consisting UV-C lamps; the 240 nm in wavelength electromagnetic emission catalyses the H2O2 radiolysis, inducing its breakage into H2O and O2.

The system can work in two different ways: in the first one, called static modality, the set VPHP concentration can be stably maintained in time for hours and days. Moreover. the elastic balance between the “hot” and “cold” responses also allows the dynamic moving across different H2O2 concentrations.

Indeed, through the second one, defined as dynamic mode, it is possible to set the time duration for a sequence of VPHP concentrations; the UL-VPHP system can automatically move toward the next pre-set concentration at the end of each phase and keep that level stable for the desired time.

https://www.comecer.com
  • Log in or register to post comments
plas-tech engineering - Supplier for COC/COP PFS Syringes
YUKON MEDICAL
TARA NIRMAN
schreiner
rochling
2 months ago
Recycling Program Turns Label Waste Into New Packaging
2 months ago
The High-Tech Secrets Behind the Humble Tin Can: A Modern Marvel of Steel Innovation
2 months ago
Recyclability Emerges as Top Priority for European Consumers, Amcor Study Finds

Follow Us

  • linkedin
  • facebook-f
  • twitter

Explore

  • Home
  • Contact Us
  • About us
  • Advertise With Us
  • Login
  • Register
  • Add Testimonial

Company

  • Blog
  • Contact Us
  • Events
  • Packaging News
  • Terms & Conditions
Top 7 Packaging Must-Haves for Personal Care Products
Top 7 Packaging Must-Haves for Personal Care Products
03 May, 2025
FDA
Navigating New FDA Packaging Regulations in 2025: A Complete Guide
29 Apr, 2025
Lamination
Unveiling the Future of Lamination Films: Trends, Challenges & How Purchasers Can Stay Ahead!
26 Apr, 2025

Footer menu

  • Privacy
  • Terms and conditions
  • Contact
Home
  • HOME
  • CONNECTIONS
    • Suppliers
    • Buyers
    • Professionals
    • User Companies
    • Softwares
    • Others
  • INDUSTRY UPDATES
    • Packaging News
    • Innovations
    • Press Releases
    • Events
    • Resources
    • Newsletter
    • Testimonials
    • Packaging Interviews
    • Packaging 4 startups
  • BLOG
  • OUR PRODUCTS
    • Big Book of Packaging
  • OUR PARTNERS
    • Bonini
    • Bernhardt
    • EMA
    • Haemotronic
    • Intin
    • Plas-Tech Engineering
    • Polycine
    • Rochling
    • Sanok Rubber
    • Schreiner
    • TARA
    • Yukon Medical
  • SERVICES
    • SUSTAINABLE EXHIBITION
    • CONSULTING
    • DESIGN SERVICES
    • NEWSLETTER SUBSCRIPTION
Clear keys input element